12 Nisan 2008 Cumartesi

kooltronic

Thermal Management for Enclosures

Coil,Icon

Air Conditioners

Closed-loop cooling of enclosures to below-ambient temperatures

Coil Fins Icon

Heat Exchangers

Closed-loop cooling of enclosures to temperatures near or above ambient temperature

Blower Icon

Basic Blowers

Open-loop cooling using ambient air circulation under moderate to high static pressures

Packaged Blower Icon

Packaged Blowers

Rack-mounted open-loop cooling using ambient air circulation under moderate to high static pressures

Fan Icon

Fans & Fan Trays

Open-loop cooling using ambient air circulation in low static pressure applicaitons

coils

Custom Cooling Design

Custom-designed cooling solutions for your unique application

New Indoor/Outdoor Profile Series Air Conditioners Mount Internally or Externally

The New Profile Series Air Conditioners are designed specifically for cooling electronic enclosures and can be used for both indoor and outdoor applications. Engineered to be mounted either outside or inside of an enclosure, the Profile Series Air Conditioners are the first Kooltronic models to offer this degree of flexibility. Also available in 480-Volt, 3-Phase configurations!

Profile Guardian/GuardianX Series Air Conditioners offer NEMA 4/4X Rating

KOOLTRONIC's new Guardian/GuardianX Series Air Conditioners offer such a high level of protection that they are used in vitrually every application imaginable.

coils
Kooltronic Product Line

Kooltronic, Inc. pioneered the development of specialized blowers and fans as well as closed-loop cooling for harsh industrial applications, with the first specially-designed Air Conditioners and Heat Exchangers for sealed enclosures introduced in the early 1960s. Since then, KOOLTRONIC has evolved into a substantial technology company, specializing in the innovative design and production of both forced ventilation and closed-loop cooling for all types of enclosures containing electronic, medical, industrial, telecommunication and other heat-producing equipment.

RoHS Compliant


enclosure cooling

Enclosure Air Conditioners

Narrow Edge Series 1,000 to 8,000 BTUH

Engineered and manufactured to endure the most difficult of environments with the depth of the enclosure in mind. The Narrow Edge Series of "Closed Loop" air conditioners is designed to fit 12" enclosures while providing 1,000 to 8,000 BTUH of cooling. Models available in NEMA Type 12, 4, and 4X. All units are cUL and UL Listed. High and low ambient protection, external alarm, dry contact remote monitoring, and integrated heater systems are some of the options available on many ISC Air Conditioners.

  • Programable Digital Temperature Controller
  • Independent Active Condensate Removal
  • Efficient Operation
  • Industrial Construction
  • Compressor Protection System

PDF LinkISC Narrow Edge Series Models and Specifications pdf


High Capacity Series 10,000 to 20,000 BTUH

ISC's High Capacity Closed Loop Air Conditioners are designed and manufactured with the same standards as our Narrow Edge Series with features like high and low refrigerant cutoffs, compressor anti short cycle protection, and compressor run capacitors, but are capable of satisfying greater cooling and heating requirements. This ever increasing series of air conditioners currently includes 10,000 BTUH to 20,000 BTUH Units and is built to last.

PDF LinkISC High Capacity Series Models and Specifications pdf


Compact Series 2,000 BTUH

Designed to fit 10" deep enclosures, measuring 20"x10"x10", this little powerhouse delivers big. While incorporating all of the features of our popular Narrow Edge air conditioners, the Compact Series models fit into places others don't.

Our Compact Series line is growing. Look for additional capacity models to be listed soon.

PDF LinkCS Specifications pdf PDF LinkCS Drawing pdf CS Drawing dwg


Hazardous Location Air Conditioner

Designed for standard and pressurized enclosures in Class 1, Div II, Groups B, C and D in hazardous locations. Includes process controll systems for chemical, petrochemical, refining, field and offshore drilling operaions. 2000 to 20000 BTUH capacities available.

PDF LinkISC Hazardous Location Air Conditioner pdf

HOFFMANN Maschinen- und Apparatbau

ChillersClick to enlargeClick to enlarge
Tailor-made chillers to fit all your needs
Continuous recirculation chiller with 4 chilling circuits

Temperature control of coolant is necessary to meet the requirements for the high quality demanded by machine tool operators. Unwanted thermal fluctuations resulting from heating of the coolant must be prevented to minimize scrapped items during manufacturing.

HOFFMANN recirculation chillers maintain and cool the temperature of:

  • drilling oils
  • hydraulic fluids
  • carrier oils
  • emulsions
  • water
  • dielectrics
  • and other fluids

Uses:

  • Machine tools
  • Hydraulic systems
  • Tempering and anodizing baths
  • Injection molding machines
  • Plastics processing machines
  • Vacuum systems
  • Transformers
  • X-ray systems
  • Erosion machining systems, etc.

Our state-of-the-art chiller units are all charged with the R 134 a refrigerant that contains no CFCs. Only materials with low reaction levels are used for the components which come into contact with the liquid being cooled. Designs with air-cooled or water-cooled motor-driven compressors can be selected.

The electric control system is located in a fully enclosed, dust-tight IP 54 switchgear cabinet, containing all of the required switching, regulating and monitoring devices, including the adjustable contact thermometer. The entire system is completely wired and ready for connection to a 400 V, 50 Hz, 3 phase or 460 V, 60 Hz, 3 phase, PE (no neutral conductor required) power supply system. The design complies with all applicable regulations and codes for industrial equipment.

Immersion-type recirculation chiller (ERK)

The medium is cooled by means of coils of tubing located below the base panel of the cooling system. Effective performance provided by air-cooled immersion chillers depends on the room air temperature (ambient temperature) and the temperature of the medium. The lower the ambient temperature, and, thus, of the available cooling air, the higher the unit's performance level. The ideal working temperature can be set to ensure uniform manufacturing quality.

All units of the ERK-V series are fitted with hermetically sealed motor-driven compressors and in the standard versions can be used for media temperatures up to+32ºC in ambient temperatures up to 38ºC. Even higher temperatures can be achieved using open or semi-hermetic motor-driven compressors.

Continuous flow through chiller (ODRK)

The coolant to be cooled is transported in the heat exchanger housing by means of a pump. The spiral, finned tube coil through which the coolant passes is located inside this housing. The coolant flows around this coil and is cooled when it exits the housing. The ideal working temperature can be selected at the continuous chiller as desired within a range of +5 to +40ºC.

Advantages:

  • Thermal stabilization
  • Reduction of scrap production
  • Enhancement of service life
  • Increase in production
  • Savings in overhead costs

We supply our recirculation chillers in compact designs ready for connection to the system, meaning that specialized installation personnel is not necessarily required.

Our application technicians will be glad to assist you with any questions or suggestions you may have. Quality, customer intimacy and on-time delivery is standard practice at HOFFMANN.



Mist collectors

Impurities in the air are produced from oil and emulsion vapors in machining areas by machine tools, at soldering and welding tables and at non-enclosed machines during machining. These impurities can be harmful to the health of the employees in these areas and can also have a negative effect on the quality of your products.

HOFFMANN mist collectors are your answer to these air pollution problems.

HOFFMANN mist collectors are high-quality devices that stand out due to their long service life and low maintenance requirements. Our systems are in line with the state of the art and have proven themselves in many years of use.

Method of operation:

function Mist collector

1.

Air intake

3.

Particulate filter section

2.

Prefilter mat

4.

Out discharge

Soiled air is drawn in directly at the source. A mechanically adjustable throttle piece regulates the amount of air to be drawn in.

The two-or three-stage prefilter and the downcircuit main filter ensure air circulation for the equipment in your machining buildings, while maintaining the stringent limits defined by the German TA-Luft (Clean Air Legislation) and MAK (Max. Workplace Concentration) regulations.

Any liquid separated out in the mist separator is routed back to the processing machine via return nozzles.

Depending on the specific requirements, and the demands of our customers, our devices can also be equipped and installed with other components:

  • acoustic hood
  • support column
  • analog or digital differential pressure indication
  • piping/tubing, etc.
  • load control system

Our application technicians will be glad to help you solve any air impurity problems you may have.

Quality, customer intimacy and on-time delivery is standard practice at HOFFMANN.